Bare Conductors includes the following Product
Range :-
- All Aluminium Conductors
- All Aluminium Alloy Conductors
- Aluminum Conductors Alloy Reinforced
- Aluminium Conductors Steel Reinforced/AW
- Stranded Copper Conductors

| ALL ALUMINIUM CONDUCTORS (AAC) |
Click here
to download the specifications |
Applications
Used as bare overhead conductor for distribution lines. Because
of its poor strength to weight ratio, AAC has limited use in Transmission
lines. AAC is extinsively used in urban areas where spans are usually
short but high conductivity is required.
Specifications
'Anvil' AAC bare conductor can be supplied to meet various
International Specifications like ASTM, BS, CSA, DIN, IEC. etc.
Construction
EC Grade hard drawn alumium wires concentrically stranded.

| ALL ALUMINIUM ALLOY CONDUCTORS (AAAC) |
Click here
to download the specifications |
Applications
Used as bare overhead conductor for power distribution lines. Designed
utilizing a high-strength aluminium alloy to achieve a high strength
-to-weight ratio; affords better sag characteristics. Aluminium
alloy gives AAAC higher resistance to corrosion than ACSR.
Specifications
'Anvil' AAAC bare conductor can be supplied to meet various
International Specifications like ASTM, BS, CSA, DIN, IEC. etc.
Construction
Aluminium alloy 6201 wires, concentrically stranded from
7 strands to 61 strands depending upon the size.

| ALUMINIUM CONDUCTOR ALUMINIUM ALLOY REINFORCED
(ACAR) |
Click here
to download the specifications |
Applications
Used as bare overhead transmission conductor or primary or secondary
distribution conductor. Where higher capacity and strength for equal
weight are prime line considerations, ACAR is the solution over
ACSR due to its better strength to weight ratio.
Specifications
'Anvil' bare ACAR conductors are tested to meet ASTM B-524
specification..
Construction
ACAR is constructed by concentrically stranding hard drawn
EC grade aluminium wires over an aluminium alloy (6201) core. In
some constructions, the aluminium alloy (6201) strands are distributed
in layers throughout the EC aluminium strands.

| ALUMINIUM CONDUCTOR STEEL RE-INFORCED |
Click here
to download the specifications |
Applications
ACSR has the established reputation for economy and dependibility
in power transmission lines. Also used for primary and secondary
distribution lines. Wide range of steel content from 7% to 40% can
be achieved by different strandings, to meet desired strength.
Specifications
'Anvil' ACSR bare conductor can be supplied to meet various
International specifications like ASTM, BS, CSA, DIN, IEC. etc.
Construction
EC Grade Aluminium wires concentrically stranded over a
steel core. The steel core wire is zinc coated. Various grades of
coating is available. The steel core can also be 'aluminized' to
produce ACSR/AZ or Aluminium clad' to produce ACSR/AW. If required
additional protection against corrosion can be provided by application
of steel core with grease.

| STRANDED COPPER CONDUCTORS |
Click here
to download the specifications |
Applications
Solid and stranded bare copper conductors are suitable for overhead
transmission and distribution applications. Stranded conductors
of greater flexibility are suitable for uninsulated hook up, jumpers
and grounds in electrical construction.
Specifications
Anvil’s bare copper wires and conductors meet the
following specifications:
- BS 7884 : 1997
- ASTM B-1; ASTM B-8
- Indian Standard
Construction
Bare copper, solid or stranded. Available in tempers hard
and annealed. The conductors are concentrically stranded. |